International Journal of Oral Implantology, 1/2024
PubMed-ID: 38501399Seiten: 59-73, Sprache: EnglischRosen, Rebecca / Haas, Robert / Millesi, Werner / Mailath-Pokorny Jr, Georg / Pohl, Sebastian / Pohl, Veronika
Background: The present retrospective study investigates implant retention time in patients who had experienced multiple implant failures and explores possible risk factors.
Materials and methods: Patients who underwent placement of at least two implants and experienced failure of two or more implants between 2004 and 2022 were included in the study population. Both patient- and implant-related risk factors, including age, sex, medical history, medication intake, smoking, alcohol consumption, implant properties and anatomical and surgical factors, were evaluated. Descriptive analysis and univariate and multivariate statistical analysis were performed to assess implant retention time and failure risk, with the level of statistical significance set at 0.05.
Results: A total of 371 patients (178 men and 193 women, median age 63 years) with 3,141 implants were included in the analysis (3.14% of all patients treated since 2004). Out of these implants, 1,090 failures were observed (59.01% of all failed implants at the Academy of Oral Implantology, Vienna, Austria), with a median retention time of 108.11 months. Patients who lost teeth due to periodontitis did not show a tendency towards early implant failure (P > 0.001). Nicotine consumption (P < 0.001), age < 50 years and > 70 years (P < 0.001), maxillary location (P = 0.05), transgingival healing (P < 0.001), no provisional restoration (P = 0.035) and short implant length (P < 0.001) were associated with statistically significantly shorter implant retention times.
Conclusions: Patients with multiple implant failures displayed cluster behaviour and had a median implant retention time of 9 years. Smoking, short implant length, single-stage surgery and immediate loading were all associated with a higher risk of failure, whereas age between 50 and 70 years and tooth loss due to periodontitis were associated with a longer implant retention time.
Schlagwörter: cluster analysis, failure analysis, implant survival, risk factors, smoking, systemic health
The authors declare their employment with the Academy of Oral Implantology, Vienna, Austria, and report no other conflicts of interest.
The International Journal of Oral & Maxillofacial Implants, 3/2022
DOI: 10.11607/jomi.9198Seiten: 508-514, Sprache: EnglischPohl, Veronika / Cede, Julia / Pokorny, Georg Benedikt Mailath / Haas, Robert / Pohl, Sebastian
Purpose: The aim of this pilot exploratory cohort study was to assess the value of buccal augmentation in immediate implant placement and immediate restoration of anterior teeth in maxillae with missing buccal lamellar bone with regard to esthetic parameters, as well as soft and hard tissue level changes.
Materials and methods: This study compared three groups of 10 patients each with immediate implant placement and immediate restoration in the anterior maxilla: (1) patients with partially to totally missing buccal bone with simultaneous augmentation with bovine collagen (test group augmented [TGA]); (2) patients with partially to totally missing buccal bone without augmentation (test group nonaugmented [TNA]); and (3) patients with intact buccal lamellar bone (control group [CG]). The pink esthetic score (PES) and the course of the peri-implant bone level after 1, 3, and 12 months were used as assessment criteria.
Results: After 12 months, the PES in the TGA was assessed as being better than it was preoperatively (mean ± SD: 8 ± 3.09 vs 9.25 ± 3.01, respectively, P = .8243), while it remained almost identical in the other two groups (TNA = 8.75 ± 2.7 vs 8.6 ± 3.3, P = .4098; CG = 10.6 ± 2.41 vs 10.6 ± 2.22, P = .7085). A significant difference among the PES values of the three groups was not observed at any point in time (preoperative: P = .118, 12 months: P = .383). In total, the TNA and CG showed an improvement in 3 out of 7 parameters of the PES after 12 months, while this was the case in 5 out of 7 parameters in the TGA. No significant difference among the three groups could be seen at any time point regarding peri-implant bone level. In the CG and TGA patients, a nonsignificant improvement in peri-implant bone level was seen after 12 months (respectively: 1.6 mm to 0.99 mm; P = .08068; 1.89 mm to 1.73 mm; P = .5866). In contrast, TNA patients showed a nonsignificant deterioration vs the postoperative situation (1.16 mm to 1.45 mm; P = .08208).
Conclusion: Within the limitations of this pilot study, it can be concluded that a missing buccal lamellar bone appears to be no contraindication for immediate implant placement and immediate restoration, provided the baseline esthetic situation is accepted. As compared to the nonaugmented defect group or the group with intact lamellar bone, neither the esthetic nor the radiologic results could be improved significantly by augmentation with bovine collagen.
Schlagwörter: buccal bone defects, esthetic zone, flapless implant surgery, immediate implants, immediate loading, maxilla
International Journal of Oral Implantology, 5/2018
SupplementPubMed-ID: 30109305Seiten: S137-S146, Sprache: EnglischPommer, Bernhard / Mailath-Pokorny, Georg / Haas, Robert / Buseniechner, Dieter / Millesi, Werner / Fürhauser, Rudolf
Aim: To review available evidence in scientific literature on oral implants of severely reduced length or diameter.
Materials and methods: Electronic and hand searches up to May 2017 were performed in order to identify clinical investigations providing implant survival and/or marginal bone resorption data for extra-short implants < 7.0 mm in length and extra-narrow implants < 3.5 mm in diameter (excluding one-piece mini-implants).
Results: A total of 2929 extra-short implants and 3048 extra-narrow diameter implants were investigated in 53 and 29 clinical studies, respectively. Shorter implants between 4.0 mm and 5.4 mm in length showed comparable results to implant lengths of 5.5 mm to 6.5 mm (95.1% vs. 96.4%, P = 0.121) and no difference regarding marginal bone resorption (0.7 mm vs 0.5 mm, P = 0.086). Implant lengths of 5.5 mm to 6.5 mm, however, performed significantly better in the mandible compared with the maxilla (P = 0.010). Smaller diameters between 3.0 mm and 3.25 mm yielded a significantly lower survival rate of 94.3% than wider implants of 3.3 mm to 3.4 mm diameter (97.7%, P < 0.001), while marginal bone resorption did not differ (0.4 mm vs 0.5 mm, P = 0.447).
Conclusions: The results of the present literature review suggest that extra-short and extra-narrow-diameter implants show satisfactory survival rates of around 95% and little marginal bone resorption of around 0.5 mm after a mean follow-up of 3 years. However, implant lengths < 7 mm in the maxilla and < 5.5 mm in the mandible as well as diameters < 3.3 mm may increase early failure rates.
Schlagwörter: decision making, dental implants, evidence-based dentistry, implant-supported dental prosthesis, patient preference
The International Journal of Oral & Maxillofacial Implants, 4/2017
DOI: 10.11607/jomi.5396, PubMed-ID: 28618434Seiten: 870-879, Sprache: EnglischPohl, Veronika / Pohl, Sebastian / Sulzbacher, Irene / Fuerhauser, Rudolf / Mailath-Pokorny, Georg / Haas, Robert
Purpose: To evaluate the use of chemically unchanged tooth material in lateral alveolar ridge augmentation or for the filling of jaw defects.
Materials and Methods: A total of 20 patients underwent either lateral augmentation of the alveolar process (11 patients) or filling of jaw defects (6 patients) with autogenous unaltered tooth material in a longitudinal 2-year study. In three patients, the jaw defect was so marked that a bone block graft had to be used for augmentation in addition to particulate dental material. In four patients, an autogenous tooth block was exclusively used; in seven, crushed tooth material was exclusively used; and in the remaining six, dystopic teeth that had been extracted were removed, crushed, and reinserted into the defect in particulate form. Fully impacted teeth served as autogenous donor teeth.
Results: After a healing time of 3 to 6 months, 28 implants could be placed (10 immediate implants, 18 delayed implants). At 6, 12, and 24 months postrestoration, peri-implant bone loss as assessed by x-ray was 0 mm, 0.4 mm, and 0.6 mm, respectively. Peri-implant probing depth was 1 mm after 1 year and 2 mm after 2 years. Bleeding on probing was not seen in any of the implants after 2 years.
Conclusion: Autogenous tooth material appears to be suitable for the restoration of lateral and intraosseous defects of the alveolar ridge with both complete blocks and in particulate form. However, additional long-term studies with higher case numbers will be required for substantiating these results.
Schlagwörter: alveolar ridge reconstruction, autogenous bone graft, autogenous tooth, bone substitutes, implants
The International Journal of Oral & Maxillofacial Implants, 5/2016
DOI: 10.11607/jomi.4326, PubMed-ID: 27632272Seiten: 1150-1155, Sprache: EnglischBusenlechner, Dieter / Mailath-Pokorny, Georg / Haas, Robert / Fürhauser, Rudolf / Eder, Carina / Pommer, Bernhard / Watzek, Georg
Purpose: To compare long-term survival and marginal bone loss of immediate interantral implants in the nonaugmented maxilla subjected to immediate vs delayed loading.
Materials and Methods: Graftless maxillary cross-arch rehabilitation was performed in a total of 362 patients in the years 2004 to 2013 (1,797 implants). Of the 240 patients with immediate implants replacing their failing maxillary dentition, 81% were subjected to immediate loading and 19% to delayed loading of their 4 to 6 interantral implants (980 and 235 implants, respectively). Kaplan-Meier survival estimates were computed and marginal bone loss was evaluated in a stratified random sample of 20 patients per group.
Results: Thirty-one of 1,215 implants failed within the mean observation period of 3.9 years, and no difference in 8-year survival estimates could be seen between immediate (97.6% [95% CI: 96.7 to 98.6]) and delayed (96.6% [95% CI: 94.3 to 98.9]) loading protocols (P = .359). Mean marginal bone resorption following implant insertion did not differ significantly between the groups (1.5 ± 1.7 mm vs 0.7 ± 1.1 mm, P = .379); however, it was significantly associated with a reduced number of implants (P = .017) and patient history of periodontal disease (P < .001).
Conclusion: Immediate loading of interantral implants yields satisfactory results in the transition of patients from a failing maxillary dentition to full-arch implant rehabilitation and thus may be favored over delayed loading concepts.
Schlagwörter: complete denture, dental implants, edentulous arch, immediate dental implant loading, implantsupported dental prosthesis, maxilla
The International Journal of Oral & Maxillofacial Implants, 4/2016
DOI: 10.11607/jomi.4325, PubMed-ID: 27447159Seiten: 900-905, Sprache: EnglischBusenlechner, Dieter / Mailath-Pokorny, Georg / Haas, Robert / Fürhauser, Rudolf / Eder, Carina / Pommer, Bernhard / Watzek, Georg
Purpose: To compare long-term survival and marginal bone loss of late interantral implants in the nonaugmented edentulous maxilla subjected to immediate vs delayed loading.
Materials and Methods: One hundred twenty-two edentulous patients with implants in native, healed jawbone were subjected to either immediate loading (179 implants) or delayed loading (403 implants) of their four to six interantral implants (part I of 362 graftless maxillary cross-arch rehabilitations performed in the years 2004 to 2013). Kaplan-Meier survival estimates were computed, and marginal bone loss was evaluated in a stratified random sample of 20 patients per group.
Results: Fifteen of 582 implants failed within the mean observation period of 4.7 years, and no difference in 8-year survival estimates could be seen between immediate (98.3% [95% CI: 96.4-100.0]) and delayed (96.7% [95% CI: 94.7-98.6]) loading protocols (P = .370). Mean marginal bone resorption following implant insertion did not differ significantly between the groups (1.1 ± 1.3 mm vs 1.4 ± 1.3 mm, P = .490).
Conclusion: Immediate loading of interantral implants in the nonaugmented edentulous maxilla yields favorable results comparable to delayed loading and may be considered to shorten periods of removable provisional prostheses in maxillary edentulism.
Schlagwörter: complete denture, dental implants, edentulous arch, immediate dental implant loading, implantsupported dental prosthesis, maxilla
The International Journal of Oral & Maxillofacial Implants, 3/2016
DOI: 10.11607/jomi.4172, PubMed-ID: 27183071Seiten: 622-630, Sprache: EnglischPohl, Veronika / Schuh, Christian / Fischer, Michael B. / Haas, Robert
Purpose: This prospective longitudinal study reports on the results in patients given autologous tooth material for augmentation in a sinus elevation procedure.
Materials and Methods: Six patients with inadequate bone supply for augmentation in the maxillary posterior tooth region and at least one impacted maxillary third molar underwent sinus elevation surgery with lateral access using the particulate tooth material. One of the patients received four implants during the same session, while the other patients had a total of 15 implants placed after a healing phase of an average 5.5 months. Drill cylinders collected from the implant bed during the procedure were subjected to histologic/immunohistochemical evaluation.
Results: All six patients showed normal and unobtrusive postoperative healing, having undergone prosthetic restoration up to 5 years before. The average peri-implant probing pocket depth after a period of up to 5 years ranged between 1.86 mm (mesial and lingual) and 2.07 mm (distal and buccal). No bleeding could be triggered with any of the peri-implant probes. The average peri-implant bone resorption measured during the first year was up to 0.63 mm, with the lowest being 0 mm and the maximum 2.9 mm. Peri-implant bone remained stable for the follow-up time of up to 5 years. Histologically, six biopsy specimens collected from five patients showed osteoconductive osteogenesis with encapsulation of tooth enamel and dentin portions and partial resorption of the tooth components. Cementum shares were no longer discernible. Immunohistochemical assessment showed intense new vessel formation that could be observed in the area of loose stroma of reorganized tissue in the augmented area.
Conclusion: Within the limits of these preliminary results and with adequate consideration of the small number of patients included, the use of autogenous crushed tooth material from impacted third molars may represent an alternative augmentation material for use in sinus elevation procedures.
Schlagwörter: augmentation, bone substitute, dental implant, dentin, enamel, sinus elevation
The International Journal of Oral & Maxillofacial Implants, 3/2016
DOI: 10.11607/jomi.4471, PubMed-ID: 27183074Seiten: 651-656, Sprache: EnglischFürhauser, Rudolf / Mailath-Pokorny, Georg / Haas, Robert / Busenlechner, Dieter / Watzek, Georg / Pommer, Bernhard
Purpose: Failing residual dentition gives rise to patient concerns about the surgical and prosthodontic management of immediate implant rehabilitation. The purpose of this study was to assess subjective patient experiences of full-arch immediate implant loading.
Materials and Methods: Patients made a transition from poor dentition in the maxilla (25 patients) or mandible (25 patients) to full-arch rehabilitation on the day of extraction using four interantral or interforaminal implants. Provisional restoration was performed, and postoperative pain, swelling, and patient-perceived impairment in the first week was recorded.
Results: Absence of pain was reported by 40%, 52%, and 66% of patients, on the day of surgery, on the first day after surgery, and on the second day after surgery, respectively; pain levels decreased significantly (from 1.8 to 0.9, P < .001) and patient-reported swelling decreased from 1.5 to 1.3 (P = .058) on a 10-point scale. Postoperative impairment of everyday life and work (mean score = 1.1) was significantly less pronounced than impairment of food intake (mean score = 2.2; P = .004) or speech (mean score = 1.9; P = .002). Of these patients, 88% would again undergo the procedure without doubt.
Conclusion: Although patient-perceived morbidity after immediate full-arch implant rehabilitation is low in general, minor masticatory and phonetic impairment should be taken into account.
Schlagwörter: complications, dental implants, immediate dental implant loading, implant-supported dental prosthesis, patient satisfaction, quality of life
The International Journal of Prosthodontics, 4/2015
DOI: 10.11607/ijp.4238, PubMed-ID: 26218027Seiten: 412-414, Sprache: EnglischPommer, Bernhard / Hingsammer, Lukas / Haas, Robert / Mailath-Pokorny, Georg / Busenlechner, Dieter / Watzek, Georg / Fürhauser, Rudolf
Prosthodontically driven biomechanical considerations are essential for longterm successful outcomes in dental implant therapy. Correct protocols seek to preclude potential consequences associated with functional and parafunctional occlusal overload such as screw loosening, component fracture, compromised marginal bone maintenance, and the integrity of the induced osseointegration response. Other concerns also need to be addressed, more especially when other implants are selected, for example: bridge insertion torque (BIT) in cases of immediate loading, cantilever length-anteroposterior spread ratio (CL-AP), overall crown-to-implant ratio (oCIR), total bone-to-implant surface area (tBICA), and the status of the opposing dentition. In spite of promising clinical results, evidencebased clinical protocols demand that such biomechanical limits still need to be determined.
International Journal of Oral Implantology, 6/2014
SupplementPubMed-ID: 24977244Seiten: 91-109, Sprache: EnglischPommer, Bernhard / Mailath-Pokorny, Georg / Haas, Robert / Busenlechner, Dieter / Fürhauser, Rudolf / Watzek, Georg
Purpose: To evaluate patient satisfaction, oral health-related quality of life, and patients' preferences towards minimally invasive treatment options for graftless rehabilitation of complete edentulism by means of dental implants.
Material and methods: A MEDLINE search of literature in the English language up to the year 2013 was performed to summarise current evidence from the patient's perspective. The final selection included 37 studies reporting on minimally invasive implant treatment of 648 edentulous maxillae and 791 edentulous mandibles in 1328 patients, via a total of 5766 implants.
Results: Patient satisfaction averaged 91% with flapless implant placement (range: 77 to 100%), 89% with short implants, 87% with narrow-diameter implants (range: 80 to 93%), 90% with a reduced number of implants (range: 77 to 100%), 94% with tilted implant placement (range: 58 to 100%), and 83% with zygomatic fixtures (range: 50 to 97%). Indirect comparison yielded patient preference towards tilted implant placement compared to a reduced number of implants (P = 0.036), as well as to zygomatic implants (P = 0.001).
Conclusions: While little evidence on patients' preferences towards minimally invasive treatment alternatives vs. bone augmentation surgery could be identified from within-study comparison, it may be concluded that patient satisfaction with graftless solutions for implant rehabilitation of completely edentulous jaws is generally high. Comparative effectiveness research is needed to substantiate their positive appeal to potential implant patients and possible reduction of the indication span for invasive bone graft surgery.
Schlagwörter: dental implants, implant-supported dental prosthesis, quality of life, patient preference, patient satisfaction
Conflict-of-interest notification: The authors declare that they have no conflict of interest.