The International Journal of Prosthodontics, 5/2023
Sólo en líneaDOI: 10.11607/ijp.7576, ID de PubMed (PMID): 36288489Páginas e88-e102, Idioma: InglésBurkhardt, Felix / Sailer, Irena / Fehmer, Vincent / Mojon, Philippe / Pitta, JoãoPurpose: To assess the influence of the bonding system and restorative material on the marginal integrity and pull-off forces of monolithic all-ceramic crowns bonded to titanium base (ti-base) abutments. Materials and Methods: A total of 108 ti-bases were sandblasted and divided into nine experimental groups (n = 12) according to the combination of crown material (polymer-infiltrated ceramic-network [PI], lithium-disilicate [LD], and zirconia [ZI]) and bonding system (Multilink Hybrid-Abutment [MH], Panavia V5 [PV], RelyX Ul5mate [RU]) with the respective primers. After bonding the crowns to the ti-base abutments, the restorations were screw-retained on implants and thermomechanically aged (1,200,000 cycles, 49 N, 1.67 Hz, 5 to 55°C). Marginal integrity and bonding failures were evaluated under a light microscope, and pull-off forces (N) were calculated. Chi-square tests for marginal integrity as well as one-way and two-way ANOVA statistical tests for pull-off forces were applied (a = .05). Results: PI presented higher marginal integrity than LD (P = .023). Bonding system PV revealed higher marginal integrity than MH (P =.005) and RU (P =.029). Differences in pull-off forces were found between restorative material and resin cements (P < .001), with the highest values for ZI + RU (598 ± 192 N), PI + PV (545 ± 114 N), LD + MH (532 ± 116 N), and PI + RU (528 ± 81 N). Specimens with marginal integrity revealed higher pull-off forces than those with alteration (P = .006). Specimens presenting bonding failures (micromovements) showed lower pull-off forces than those without bonding failures (P < .001). Conclusions: The tested CAD/CAM materials show favorable bonding performances with different bonding systems, nevertheless for each restorative material a specific bonding system has to be recommended. Int J Prosthodont 2023;36:e88–e102
International Journal of Computerized Dentistry, 4/2022
ScienceDOI: 10.3290/j.ijcd.b2599407, ID de PubMed (PMID): 35072424Páginas 349-359, Idioma: Inglés, AlemánBrandenburg, Leonard Simon / Schwarz, Steffen Jochen / Spies, Benedikt Christopher / Weingart, Julia Vera / Georgii, Joachim / Jung, Britta A. / Burkhardt, Felix / Schlager, Stefan / Metzger, Marc ChristianPurpose: Creating wax-ups of missing teeth for backward planning in implant surgery is a complex and time-consuming process. To facilitate implant-planning procedures, the automatic generation of a virtual wax-up would be useful. In the present study, the reconstruction of missing teeth in partially edentulous patients was performed automatically using newly developed software. The accuracy was investigated in order to test its clinical applicability.
Materials and methods: This study presents a new method for creating an automatic virtual wax-up, which could serve as a basic tool in modern implant-planning procedures. First, a statistical shape model (SSM) based on 76 maxillary and mandibular arch scans from dentally healthy individuals was generated. Then, artificially generated tooth gaps were reconstructed. The accuracy of the workflow was evaluated on a separate testing sample of 10 individuals with artificially created tooth gaps given as a median deviation, in millimeters. Scans of three clinical cases with partial edentulism were equally reconstructed using the SSM and compared with the final prosthodontic work.
Results: The reconstruction of the artificial tooth gaps could be performed with the following median reconstruction accuracy: gap 21 with 0.15 mm; gap 27 with 0.20 mm; gap 34 with 0.22 mm: gap 36 with 0.22 mm; gaps 12 to 22 with 0.22 mm; gaps 34 to 36 with 0.22 mm. A scenario for an almost edentulous mandible with all teeth missing except teeth 33 and 43 could be reconstructed with a median reconstruction accuracy of 0.37 mm. The median tooth gap deviation of the SSM-based reconstruction in clinical cases differed from the final inserted prosthodontic teeth by 0.49 to 0.86 mm in median.
Conclusion: A first feasibility of creating virtual wax-ups using an SSM could be shown. Artificially generated tooth gaps could be reconstructed close to the original with the proposed workflow. In the clinical cases, the SSM proposes an anatomical reconstruction, which does not yet consider prosthodontic aspects. To obtain clinical use, contact with antagonist teeth must be considered and more training data must be implemented. However, the presented method offers a fast and viable way for the approximate placement of missing crowns. This could be used in a digital planning workflow when implant position must be determined. (Int J Comput Dent 2022;25(4):349–0; doi: 10.3290/j.ijcd.b2599407)
Palabras clave: statistical shape model, virtual wax-up, partial edentulism, accuracy, implant planning
Team-Journal, 1/2021
KOMPETENZ PLUSPáginas 6-16, Idioma: AlemánFehmer, Vincent / Burkhardt, Felix / Sancho-Puchades, Manuel / Hämmerle, Christoph / Sailer, IrenaDie Diagnostik ist entscheidend für den vorhersagbaren Erfolg einer restaurativen Therapie. Hierbei müssen sich Patient und Zahnarzt vor der Anfertigung der definitiven Restauration auf ein gemeinsames Behandlungsziel einigen, um später Enttäuschungen zu vermeiden. Allerdings kann es schwierig sein, die Patientenwünsche vollständig zu erfassen. Ein nützliches Hilfsmittel zur Lösung dieses Problems sind das diagnostische Wax-up und Mock-up. Mit diesem zeitaufwendigen Verfahren wird jedoch nur eine einzige Variante des möglichen Behandlungsergebnisses visualisiert. Die moderne Digitaltechnik bietet nützliche Funktionen, die bei diesem diagnostischen Schritt zu einer Entscheidungsfindung beitragen können. Im vorliegende Beitrag werden die Möglichkeiten der Digitaltechnik für die prothetische Diagnostik erörtert und die Verfahren anhand von Patientenfällen beschrieben.
QZ - Quintessenz Zahntechnik, 1/2021
Exzellente Dentale ÄsthetikPáginas 7-8, Idioma: AlemánPiskin, Cem / Burkhardt, FelixThe International Journal of Prosthodontics, 5/2020
DOI: 10.11607/ijp.6778, ID de PubMed (PMID): 32956436Páginas 546-553, Idioma: InglésPitta, João / Bijelic-Donova, Jasmina / Burkhardt, Felix / Fehmer, Vincent / Närhi, Timo / Sailer, IrenaPurpose: To evaluate the effect of cementation protocols on the bonding interface stability and pull-out forces of temporary implant-supported crowns bonded on a titanium base abutment (TiB) or on a temporary titanium abutment (TiA).
Materials and Methods: A total of 60 implants were restored with PMMA-based CAD/CAM crowns. Five groups (n = 12) were created: Group 1 = TiB/SRc: crown conditioned with MMA-based liquid (SR Connect, Ivoclar Vivadent); Group 2 = TiB/50Al-MB: crown airborne particle–abraded with 50-μm Al2O3 and silanized (Monobond Plus, Ivoclar Vivadent); Group 3 = TiB/30SiOAl-SRc: crown airborne particle–abraded with 30-μm silica-coated Al2O3 (CoJet, 3M ESPE) and conditioned with MMA-based liquid (SR Connect); Group 4 = TiB/30SiOAl-MB: crown airborne particle–abraded with 30- μm silica-coated Al2O3 (CoJet) and silanized (Monobond Plus); and Group 5 = TiA/TA-PMMA: crown manually enlarged, activated, and rebased with PMMA resin (Telio Lab, Ivoclar Vivadent). Specimens in the TiB groups were cemented using a resin cement (Multilink Hybrid Abutment, Ivoclar Vivadent). After aging (120,000 cycles, 49 N, 1.67 Hz, 5°C to 55°C, 120 seconds), bonding interface failure was analyzed (50x). Pull-out forces (N) (0.5 mm/minute) and modes of failure were registered. Chi-square and Kruskal-Wallis tests were used to analyze the data (α = .05).
Results: Bonding failure after aging varied from 0% (Group 5) to 100% (Groups 1, 2, and 4) (P .001). Mean pull-out force ranged between 53.1 N (Group 1) and 1,146.5 N (Group 5). The pull-off forces were significantly greater for Group 5 (P .05), followed by Group 3 (P .05), whereas the differences among the remaining groups were not significant (P > .05).
Conclusion: The cementation protocol had an effect on the bonding interface stability and pull-out forces of PMMA-based crowns bonded on a titanium base. Airborne particle abrasion of the crown internal surface and conditioning it with an MMA-based liquid may be recommended to improve retention of titanium base temporary restorations. Yet, for optimal outcomes, conventional temporary abutments might be preferred.
QZ - Quintessenz Zahntechnik, 5/2020
ErfahrungsberichtPáginas 510-527, Idioma: AlemánFehmer, Vincent / Burkhardt, Felix / Sancho-Puchades, Manuel / Hämmerle, Christoph / Sailer, IrenaDie Diagnostik ist entscheidend für den vorhersagbaren Erfolg einer restaurativen Therapie. Hierbei müssen sich Patient und Zahnarzt vor der Anfertigung der definitiven Restauration auf ein gemeinsames Behandlungsziel einigen, um später Enttäuschungen zu vermeiden. Allerdings kann es schwierig sein, die Patientenwünsche vollständig zu erfassen. Ein nützliches Hilfsmittel zur Lösung dieses Problems sind das diagnostische Wax-up und Mock-up. Mit diesem zeitaufwendigen Verfahren wird jedoch nur eine einzige Variante des möglichen Behandlungsergebnisses visualisiert. Die moderne Digitaltechnik bietet nützliche Funktionen, die bei diesem diagnostischen Schritt zu einer Entscheidungsfindung beitragen können. Im vorliegende Beitrag werden die Möglichkeiten der Digitaltechnik für die prothetische Diagnostik erörtert und die Verfahren anhand von Patientenfällen beschrieben.
Palabras clave: CAD/CAM, Mock-up, Visualisierung, additive Fertigung, 3-D-Druck
The International Journal of Prosthodontics, 4/2020
DOI: 10.11607/ijp.6402, ID de PubMed (PMID): 32639697Páginas 380-385, Idioma: InglésLee, Hyeonjong / Burkhardt, Felix / Fehmer, Vincent / Sailer, IrenaPurpose: To test the accuracies of different methods of digital vertical dimension augmentation (VDA) by comparison with a clinical situation.
Materials and Methods: Bite registrations with approximately 5 mm of VDA were made in the incisor regions of 10 subjects (mean VDA 4.5 mm). The conventional maxillary and mandibular stone casts in maximum intercuspation (MICP) and VDA bite registrations were digitized for all subjects using a laboratory scanner (control group). Lateral portraits were taken of all subjects to locate the position of the condylar axis. Four different digital VDA methods were compared to the control group: 100% rotation of the mandible referring to the lateral picture (100RL); 85% rotation and 15% translation referring to the lateral picture (85R15TL); 100% rotation in normal mounting mode of the Trios virtual articulator (100R); and jaw-motion analysis (JMA) equipment. The amount of VDA for each experimental group was compared to the control group. The augmented distances between the central incisors and the second molars were measured using 3D analyzing software. The ratio of the augmented distances between the posterior and anterior regions (P/A ratio) was calculated. One-way analysis of variance and multiple comparisons via least significant difference test were carried out to determine statistical significance.
Results: The P/A ratio of each group was as follows: Control = 0.61; 100RL = 0.55; 85R15TL = 0.61; 100R = 0.53; JMA = 0.52. Significant differences were observed for control vs JMA and for 85R15TL vs JMA (P .05). The addition of translational movement was the primary factor for increasing the accuracy of digital VDA, with the lateral picture being a secondary factor.
Conclusion: VDA using a virtual articulator with 100% rotation induces an error when compared to the clinical situation. When a clinician performs digital VDA, the setting of 85% rotation and 15% translation produces results closer to the real clinical condition.
International Journal of Computerized Dentistry, 1/2020
ApplicationID de PubMed (PMID): 32207463Páginas 73-82, Idioma: Alemán, InglésBurkhardt, Felix / Strietzel, Frank Peter / Bitter, Kerstin / Spies, Benedikt ChristopherHintergrund: Für den Behandlungserfolg einer implantatprothetischen Versorgung ist die Positionierung der Implantate im Knochen von hoher Bedeutung. Insbesondere bei einteiligen Implantaten ist eine nachträgliche Korrektur der Implantatachse nur erschwert möglich. Eine prothetisch orientierte, digitale Planung in Kombination mit einer vollgeführten Implantation kann in diesem Fall ein erhöhtes Maß an Sicherheit bieten.
Fallpräsentation: Zur Rehabilitation einer weitspannigen Schaltlücke in Regio 13 bis 16 wurden drei einteilige Implantate aus Zirkonoxid zur Aufnahme einer Zirkonoxidbrücke mit Extensionsbrückenglied geplant. Für eine optimale Positionierung basierte die Planung auf einem digitalen Set-up und dreidimensionalen DICOM-Daten (Digital Imaging and Communications in Medicine). Die geführte Implantatinsertion wurde mithilfe von Aufsätzen am chirurgischen Winkelstück sowie einer dazu kompatiblen, hülsenlosen Bohrschablone durchgeführt. Für die definitive Versorgung erfolgte die Abformung der Implantate mittels Intraoralscanner. Hierbei auftretende reflexionsbedingte Ungenauigkeiten wurden durch eine digitale Abutmentgeometrie ausgeglichen. Auf Basis dieser überlagerten STL-Daten wurde eine monolithische Zirkonoxid-Restauration subtraktiv gefertigt und adhäsiv zementiert.
Schlussfolgerung: Aufgrund einer vorausschauenden, prothetisch orientierten Planung konnten die einteiligen Keramikimplantate auch ohne Guide-Lösung des Implantatherstellers inseriert werden. Dies war mithilfe von Aufsätzen am chirurgischen Winkelstück und einer dazu kompatiblen Bohrschablone möglich. Dies ist besonders bei einteiligen Implantaten empfehlenswert, da eine nachträgliche Korrektur der Implantatachse nur durch irreversibles Beschleifen der Abutments möglich ist. Durch die Überlagerung der Scandaten mit der importierten, idealen Abutementgeometrie konnte die Genauigkeit der Implantatabformung verbessert werden. Es konnte gezeigt werden, dass mithilfe dieser Methode zukünftig auf eine Gingivaretraktion bei der Abformung dieses Implantattyps verzichtet werden kann.
Palabras clave: Keramikimplantate, geführte Implantation, backward planning, Intraoralscan, CAD/CAM, digitaler Workflow
QZ - Quintessenz Zahntechnik, 7/2019
StatementPáginas 906-907, Idioma: AlemánBurkhardt, Felix / Fehmer, VincentDentista, 2/2019
FokusPáginas 21-23, Idioma: AlemánBurkhardt, Felix / Fehmer, Vincent / Sailer, Irena / Pjetursson, Bjarni E.Eine systematische Literaturübersicht