Pages 33-43, Language: EnglishWang / Welsch / Castro-CedenoPurpose: Dental casting requires replication of complex shapes with high fidelity. To achieve this objective, the problem of scale formation on titanium dental castings must be overcome. Scaling occurs readily at high temperatures because of the high reactivity of molten titanium with investment materials. The purpose of this study was to examine the effectiveness of using stable oxide coatings on the mold surface to reduce the interfacial reactions. Materials and Methods: A traditional phosphate-bonded dental investment, a commercial titanium investment, and an experimental oxide coating were used for the molds. Pure titanium samples were cast, divested, and prepared for scanning electron microscopic and energy dispersive x-ray spectroscopic analyses. Results: Layers of 7- to 10-um-thick scale were formed on titanium castins during reaction with traditional mold materials. Interface reaction was reduced between the molten titanium and the investment material when yttrium oxide or zirconium oxide coatings were applied to the mold before casting. Conclusion: Less titanium-mold interfacial reactions occurred when protective coatings were used as diffusion barriers for titanium casting. Y2O3-coating oxide particles applied withotu binder were entrapped in the cast titanium surface layer. Further study of a binder system for Y2O3 coating is needed.