PubMed-ID: 17465345Seiten: 208-212, Sprache: EnglischLee, Scott / Gantes, Bernard / Riggs, Matt L. / Crigger, MaxPurpose: In previous publications of this series of studies on human cadaver jaws, bone densities were assessed and compared using subjective evaluation, conventional computed tomography (CT), and cone-beam computed tomography (CBCT). The aim of this study was to compare subjective bone quality during osteotomy and implant insertion resistance torque to noninvasive subjective and objective radiographic bone density assessments.
Materials and Methods: Forty-two designated implant sites were selected. Self-tapping implants were inserted into these sites. The operator subjectively rated the bone density during the osteotomy procedure. Resistance torque was recorded during insertion of the implants.
Results: Subjective drilling resistance was modestly correlated to subjective radiographic density evaluation (Lekholm and Zarb; Spearman's rho of 0.53, P .001). Subjective drilling resistance compared to the bone density in Hounsfield units (HU) obtained using CT and CBCT showed correlation coefficients of 0.61 and 0.59, respectively (P .001). Significant overlap of density values was found for adjacent drilling ratings. On average, a difference in bone density of 180 HU was required to identify differences between drilling resistance groups. Comparisons of 2 implant insertion resistance torque variables (highest reading and regression slope of available readings) with CT and CBCT HU showed correlation coefficients of 0.61 to 0.63 (P .01).
Conclusion: Insertion torque resistance was modestly correlated with objective CT and CBCT measurements of bone density. The merit of these assessments of cadavers awaits clinical study.
Schlagwörter: bone quality, dental implants, implant placement, radiographic bone density, resistance torque