Irena Sailer, Prof Dr med dent, is chair of the Division of Fixed Prosthodontics and Biomaterials at the University of Geneva and adjunct associate professor in the Department of Preventive and Restorative Sciences at the University of Pennsylvania School of Dental Medicine. In 2019, she received an Honorary Skou Professorship of digital dental technologies, fixed and implant prosthodontics, and biomaterials at Aarhus University, Denmark. Dr Sailer is editor-in-chief of The International Journal of Prosthodontics and coauthor of over 150 peer-reviewed publications as well as the books Fixed Restorations: A Clinical Guide to the Selection of Materials and Fabrication Technology (Quintessence, 2021) and Color in Dentistry (2017). She holds several patents on esthetic coatings of dental/medical devices and a digital dental splint.
A Clinical Guide to the Selection of Materials and Fabrication Technology
1st Edition 2021 Book Hardcover, 23,5 x 30,5 cm + 5 doublesided inserted cards, 744 pages, 2750 illustrations Language: English Categories: Restorative Dentistry, Prosthodontics, Dental Technology ISBN 978-1-78698-027-4 QP Deutschland
1. Auflage 2008 Book Hardcover, 136 pages, 218 illustrations Language: German Categories: Prosthodontics, Dental Technology ISBN 978-3-938947-69-2 QP Deutschland
The 15th International Symposium on Periodontics and Restorative Dentistry (ISPRD)
June 12, 2025 — June 15, 2025Boston Marriott Copley Place, Boston, MA, United States of America
Speakers: Edward P. Allen, Evanthia Anadioti, Gustavo Avila-Ortiz, Christopher Barwacz, Florian Beuer, Nitzan Bichacho, Francesco Cairo, Vivianne Chappuis, Chia-Yu (Jennifer) Chen, Stephen J. Chu, Florin Cofar, Daniel Coleman, Luca Cordaro, Daniel Cullum, Luca De Stavola, Carlo Ercoli, Vincent Fehmer, Iñaki Gamborena, Maria L. Geisinger, William Giannobile, Luca Gobbato, Oscar Gonzalez-Martin, Jim Janakievski, Y. Natalie Jeong , Ronald Jung, Joseph Kan, Jihyon Kim, Gregg Kinzer, Christopher Köttgen, Ina Köttgen, Stefen Koubi, Purnima S. Kumar, France Lambert, Alejandro Lanis, Ernesto A. Lee, Paul Levi Jr, Tomas Linkevičius, Pascal Magne, Pamela Maragliano-Muniz, Konrad H. Meyenberg, Craig M. Misch, Ricardo Mitrani, Rodrigo Neiva, Giorgio Pagni, Gianluca Paniz, Giulio Rasperini, Pooyan Refahi, Andrea Ricci, Marisa Roncati, Paul S. Rosen, Irena Sailer, Mariano Sanz, Ignacio Sanz Martín, Ignacio Sanz Sànchez, Todd Scheyer, Frank Schwarz, Massimo Simion, Frank Spear, Martina Stefanini, Clint Stevens, Lorenzo Tavelli, Tiziano Testori, Sejal Thacker, Teppei Tsukiyama, Istvan Urban, Eric Van Dooren, Diego Velasquez, Hom-Lay Wang, Giovanni Zucchelli, Otto Zuhr
Quintessence Publishing Co., Inc. USA
This author's journal articles
The International Journal of Prosthodontics, 3/2025
DOI: 10.11607/ijp.2025.3ePages 277-278, Language: EnglishSailer, Irena
Purpose: To evaluate the wear resistance of a printed interim resin manufactured with different printing and postpolymerization parameters. Materials and Methods: Overall, 130 rectangular resin specimens (15 × 10 × 10 mm) were 3D-printed. Among the specimens, 60 were printed with different printing orientations (0, 45, and 90 degrees) and layer thicknesses (50 and 100 μm) to create six groups to investigate the effects of the printing parameters (n = 10 per group). The remaining 70 specimens were used to evaluate the effects of postpolymerization; for this, seven groups were created as follows (n = 10 per group): nonpostpolymerized; postpolymerized for 5, 15, and 30 minutes with an ultraviolet light–emitting diode (LED) device; and postpolymerized for 5, 15, and 30 minutes with an ultraviolet light bulb device. After masticatory simulation, the wear volume loss was calculated with 3D metrology software. One-way and two-way ANOVA were used for intergroup comparisons (α = .05). Results: The group printed with a build angle of 45 degrees showed lower wear volume loss than the 0- and 90-degree groups (P < .01). The wear volume loss in the ultraviolet LED group was significantly greater than that in the ultraviolet light bulb group (P = .04). No significant difference was observed in the wear volume loss of the printed resin with respect to the layer thickness and polymerization time (P > .05). However, the non-postpolymerized group showed significantly greater wear volume loss than the other groups (P < .001). Conclusions: The printed resin showed greater wear resistance when it was printed at a build angle of 45 degrees and postpolymerized with an ultraviolet light bulb device.
Purpose: To evaluate the accuracy of complete-arch digital implant impressions using different intraoral scan body (ISB) materials and intraoral scanners (IOSs). Materials and Methods: The mandibular dental cast of an edentulous patient with six tissue-level dental implants was used as the master cast. Two types of ISBs—polyether ether ketone (PEEK) and plasma-coated medical titanium—were used with five IOSs: TRIOS 4 (T4), Virtuo Vivo (VV), Medit i700 (Mi700), iTero 5D (i5D), and Primescan (PS). To assess accuracy, digital impressions (n = 10) with each IOS and ISB were compared to two reference models obtained by digitizing the master cast with each ISB type using a desktop scanner (IScan4D LS3i) and importing the scan data into metrology software (Geomagic Control X). Root mean square (RMS) error was employed to evaluate overall deviation values (trueness), while precision was determined using the SD of RMS values. Statistical significance was set at P < .05. Kruskal-Wallis test was used, followed by the pairwise comparison method with Bonferroni correction (α = .05). Results: An interaction between ISB material and IOS was found (P = .001). Plasma-coated medical titanium ISBs demonstrated significantly higher trueness and precision compared to PEEK ISBs with T4 (P = .001), Mi700 (P = .001; P = .004), and i5D (P = .001). Conversely, VV exhibited higher trueness and precision values with PEEK ISBs (P = .005; P = .003). PS provided the highest trueness and precision regardless of the ISB material (P = .912). T4 showed the lowest accuracy for PEEK ISBs, and VV showed the lowest accuracy for plasma-coated medical titanium ISBs. Conclusions: Except for PS, all IOSs showed significant differences between ISB materials. PS demonstrated the highest accuracy with both ISB materials, whereas T4 had the lowest accuracy for PEEK ISBs, and VV showed the lowest accuracy for plasma-coated medical titanium ISBs.
The International Journal of Oral & Maxillofacial Implants, 4/2024
Online OnlyDOI: 10.11607/jomi.10656, PubMed ID (PMID): 37939237Pages e121-e128, Language: EnglishMarchand, Laurent / Cornish, David / Mojon, Philippe / Sailer, Irena / Worni, Andreas
Purpose: To measure the surface temperature distribution after using a CO2 laser to heat titanium dental implants via different power settings, application intervals, and irradiation times. Materials and Methods: A total of 10 tissue-level titanium implants (Screw-Line Promote Plus, Camlog; 4.3 × 11 mm) were placed (EpoFix, Struers) and irradiated with a CO2 laser (Denta 2, Lutronic) with a wavelength of 10.6 μm at power levels of 4 watts (Group 1), 6 watts (Group 2), 8 watts (Group 3), and 10 watts (Group 4). A continuous beam mode (setting I) and noncontinuous beam modes with 5-second (setting II) and 10-second (setting III) pause intervals were used. For each setting, a total irradiation time of 50 seconds was used and repeated 10 times. The temperature was measured using external thermocouple (Testo) in contact with the implant surface at the implant shoulder, middle, and apex. A linear regression model was used to analyze the data (P = .05). Results: Setting I demonstrated the most rapid increase in implant surface temperature in all three test sites as well as the greatest total temperature at 50 seconds of irradiation time. The greater the pause interval (settings II and III) during the 50 seconds of irradiation, the lower the rate of temperature increase as well as the total temperature in all three test sites and with all power levels. The average temperature difference between the apex and shoulder site was significant for setting III for all groups, but not for any groups in settings I and II. Conclusions: Heating the internal aspect of an implant with a CO2 laser produces different temperature distribution profiles depending on the laser power level and the application interval. Laser-beam irradiation leads to a temperature gradient, which is greatest at the implant apex and smallest at the implant shoulder.
The International Journal of Prosthodontics, 2/2024
DOI: 10.11607/ijp.8852, PubMed ID (PMID): 38270461Pages 221-224, Language: EnglishRevilla-León, Marta / Barmak, Basir A. / Sailer, Irena / Kois, John C. / Att, Wael
Purpose: To compare the performance of licensed dentists and two software versions (3.5 legacy and 4.0) of an artificial intelligence (AI)-based chatbot (ChatGPT) answering the exam for the 2022 Certification in Implant Dentistry of the European Association for Osseointegration (EAO). Materials and Methods: The 50-question, multiple-choice exam of the EAO for the 2022 Certification in Implant Dentistry was obtained. Three groups were created based on the individual or program answering the exam: licensed dentists (D group) and two software versions of an artificial intelligence (AI)-based chatbot (ChatGPT)—3.5 legacy (ChatGPT-3.5 group) and the 4.0 version (ChatGPT-4.0 group). The EAO provided the results of the 2022 examinees (D group). For the ChatGPT groups, the 50 multiple-choice questions were introduced into both ChatGBT versions, and the answers were recorded. Pearson correlation matrix was used to analyze the linear relationship among the subgroups. The inter- and intraoperator reliability was calculated using Cronbach’s alpha coefficient. One-way ANOVA and Tukey post-hoc tests were used to examine the data (α = .05). Results: ChatGPT was able to pass the exam for the 2022 Certification in Implant Dentistry of the EAO. Additionally, the software version of ChatGPT impacted the score obtained. The 4.0 version not only pass the exam but also obtained a significantly higher score than the 3.5 version and licensed dentists completing the same exam. Conclusions: The AIbased chatbot tested not only passed the exam but performed better than licensed dentists.